video
Closed Suctioning System

Closed Suctioning System

Trifanz closed suctioning system is available for 24 hour or 72 hour usage depending on patient requirements. There are two length options to allow attachment to either endotracheal tube (long length 600mm)or tracheostomy tubes (short length 305mm).

Product Introduction

Closed suctioning system enables a clinician to clear the lungs of secretions whilst maintaining ventilation and minimizing contamination with the least possible disruption to the patient.

 

Product Benefits

 

  1. Allow for suctioning a patient on a ventilator without loss of PEEP or mean airway pressure.
  2. 72 hour recommended duration of use.
  3. Clear pathway evacuation port.
  4. Lockable thumb valve end cap.
  5. Sterile, single patient use.
  6. Patient label with day of the week stickers
  7. Closed catheter sleeve.
  8. Swivel connector available to aid in reduced torque.
  9. Available in Endotracheal and Tracheostomy tube configurations
  10. Color coded rings provide fast size recognition

 

Specification

 

 

72h closed suction system
72h clsoed suction system1

 

Size

Type

REF No.

Length for Endotracheal Tube

Length for Tracheostomy Tube

Color

6Fr

Adult-72 hours

98.09.040

540mm

305mm

Light Green

8Fr

98.09.043

540mm

305mm

Blue

10Fr

98.09.046

540mm

305mm

Black

12Fr

98.09.049

540mm

305mm

White

14Fr

98.09.052

540mm

305mm

Green

16Fr

98.09.055

540mm

305mm

Orange

 

 

24h closed suction system
24h closed suction system1

 

Size

Type

REF No.

Length for Endotracheal Tube

Length for Tracheostomy Tube

Color

6Fr

Adult-24 hours

98.09.022

540mm

305mm

Light Green

8Fr

98.09.025

540mm

305mm

Blue

10Fr

98.09.028

540mm

305mm

Black

12Fr

98.09.031

540mm

305mm

White

14Fr

98.09.034

540mm

305mm

Green

16Fr

98.09.037

540mm

305mm

Orange

Remark: the length of closed suction system could be customized

 

72h closed suction system VS 24h closed suction system

 

Item name

72h closed suction system

24h closed suction system

Picture

72h clsoed suction system1

24h closed suction system1

Differences

With isolation valve and week stickers, reusable within 72hours

Without isolation valve and week stickers, reusable within 24hours

Advantages

Made of medical grade PVC

PU protecting film, without welding edge, more safety

With washing port and MDI injection port

The connector is 360°rotatable, very flexible

Suction tube with length marked, easy to see the intubating depth

Patent design on single hand lock button

 

Detail picture

 

 

The difference between 72h type & 24h type closed suction system

closed suction tube~1
mark on closed suction system~1

 

Clear mark on the tube

 

Packaging: individual paper-plastic pouch, EO sterile, carton size 52*39*35cm, 100pcs/carton

Packaging of closed suction system
FAQ
 

Q: What are the advantages of a closed suction system?

A: The suggested advantages of CTSS compared to conventional OTSS are: improved oxygenation; decreased clinical signs of hypoxemia; maintenance of positive end-expiratory pressure; limited environmental, personnel and patient contamination; and smaller loss of lung volume.

Q: How long can an adult patient be suctioned at one time?

A: After inserting the catheter the measured distance initiate suctioning as you retract the catheter in a sweeping motion. Do not suction too long! The maximum suction time should only be 15 seconds. After suctioning, re-oxygenate the patient.

 

Hot Tags: closed suctioning system, China closed suctioning system manufacturers, suppliers, factory, Closed Suction Tube 72 Hours, Closed Suctioning System, Closed Suction Endotracheal Tube, Closed Suction Tube, Closed Trach Suctioning, Closed Suction Tube 24 Hours

Send Inquiry

whatsapp

Phone

E-mail

Inquiry

Bag